Drager Fabius MRI


Certified Refurbished Medical Equipment!

Drager Fabius MRI Features
The Drager Fabius MRI is an anaesthesia machine that is compatible with an MRI Machines. I can be used with MRI Systems of 1.5 and 3 Tesla. The Fabius MRI offers a variety of ventilation modes including volume and pressure. The Drager MRI Anaesthesia Machine comes with an E-vent piston-controlled ventilator – this can deliver a maximum peak flow of ventilation and does not require a drive gas. The anaesthesia Machine has a large, high-visibility colour screen along with an integrated warning and alarm LED system.

Drager Fabius MRI Features
The Drager Fabius MRI is an anaesthesia machine that is compatible with an MRI Machines. I can be used with MRI Systems of 1.5 and 3 Tesla. The Fabius MRI offers a variety of ventilation modes including volume and pressure. The Drager MRI Anaesthesia Machine comes with an E-vent piston-controlled ventilator – this can deliver a maximum peak flow of ventilation and does not require a drive gas. The anaesthesia Machine has a large, high-visibility colour screen along with an integrated warning and alarm LED system.

High visibility colour screen.
Integrated Warning and alarm LEDs.
2 vaporizer mount.
Pressure gauges for pin index gas cylinders.
Dräger Sob CLIC absorber.
Anesthetic Gas Scavenging System.
3 Large drawers, 1 with lock.
Central brake.
Compact Breathing System.
E-vent piston Ventilator.
Dräger Fabius MRI Specifications
Base Unit
Trolley Version (Cart) with COSY: Dimensions (W × H × D): approximately 39 × 55 × 35.5 in. (99 × 140 × 90 cm)
Fabius MRI Trolley (with COSY) Weight and load without supplementary cylinders and vaporizers: 365 lbs. (165.8 kg)
Power and Battery Backup
Power Input: 100 to 240 VAC, 50 / 60 Hz, 70 VA, including additional power outlets.
Operation time with fully charged batteries: > 45 min.
Anesthesia Gas Supply Module
Range of fresh gas flow indicators: 0.0 to 12.0 L/min Total fresh gas flowmeter 0 to 10 L/min.
O2 flush: at 87 psi (6 bar): max 75 L/min; at 41 psi (2.8 bar): min. 25 L/min.
Vaporizer: 2 position Dräger mount (Interlock 2 – System): Dräger Isoflurane Vapor 2000, Dräger Sevoflurane Vapor 2000, Dräger Halothane Vapor 2000, Dräger Enflurane Vapor 2000.
Ventilator Operating Specifications
Ventilator E-vent: Electronically controlled, electrically driven.
Operating modes: Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, SIMV/PS, Manual Ventilation, Spontaneous Breathing.
Control Input Ranges
Breathing Frequency (rate): 4 to 60 bpm.
Positive End Expiratory Pressure (PEEP): 0 to 20 cmH2O (hPa).
Inspiration/expiration ratio (Ti:Te): 4:1 to 1:4.
Pressure limiting (Pmax): 15 to 70 cmH2O (hPa).
Tidal Volume (Vt): 20 to 1400 mL in Volume Control, 20 to 1100 mL in SIMV/PS.
Inspiration pause (Tip:Ti): 0 to 50 %.
SIMV Inspiratory time: 0.3 – 4.0 sec.
Inspiratory pressure (Pinsp): PEEP + 5 to 65 cmH2O (hPa).
Inspiratory Flow (InspFlow): 10 to 75 L/min in Volume and Pressure Control modes, 10 to 85 L/min in Pressure Support and SIMV/PS modes.
Pressure Support Level (PPS): PEEP + 3 to 20 cmH2O (hPa) Min. frequency for apnoe-ventilation (Freq. Min.) 3 to 20 bpm and “OFF”.